Activity
Mon
Wed
Fri
Sun
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Jan
Feb
Mar
What is this?
Less
More

Owned by Jason

The Substrate Academy

62 members • Free

Stop flooring failures before they start. Master moisture testing, surface prep, self-leveling, and mitigation alongside other serious flooring pros.

Memberships

47 contributions to The Substrate Academy
Osmotic Blistering
Simply put: Moisture + salts + a sealed surface = hydraulic pressure that pushes the coating off the slab.
0
0
Osmotic Blistering
Quad Skid Gauge Rake
Gauge uneven surfaces with the confidence of 4 points of contact. Stainless-steel gauge rake body that accepts four interchangeable Skid Gauges designed to work at varying angles instead of just perpendicular and also be more forgiving of a rough application surface at depths of ⅛ – ⅜ in. (3 – 10 mm) across a full 24 in. (600 mm) path. See more at Portamix.com for a range of levelling tools.
Quad Skid Gauge Rake
0 likes • 21d
@Keith Langskov Yeah I share the same sentiments about it, I’m going to order these and give them a try.
0 likes • 22d
@Roland Vierra Nice! Thanks for sharing this with the community R.V!
NuCore Moisture Testing Requirements
They only call out ASTM 2659, that’s moisture meter guys. Here’s what it says: Although this floor is waterproof, from the top down, it is not to be used as a moisture barrier. The subfloor must be dry. Concrete moisture vapor emissions should not exceed 2.5% moisture content (ASTM F2659 method). Prior to installing flooring, remove dirt, paint, varnish, wax, oils, solvents, any foreign matter and contaminants from the subfloor. Do not use products containing petroleum, solvents or oils to prepare subfloors as they can cause staining and expansion of the new flooring. Link: https://flooranddecor.a.bigcontent.io/v1/static/NuCorePerformanceWarrantyandInstallationInstructionsMixedWidths110-144-178
1 like • 22d
@Chris Raynor No, I don’t use RC. Been using 6-mil for over 10 years. Zero problems.
0 likes • 22d
@Roland Vierra 💯
🚨 OFFICIAL LAUNCH 🚨
The Tramex Certified Time‑of‑Install Moisture Technician – Level 1 Program is now open. Written Exam ✅ Practical Field Demonstration ✅ Certification ✅ This program verifies: • Environmental evaluation • Dew point interpretation • Grid methodology • Pattern recognition • Documentation standards This is structured field competency. Enrollment is open. Go to the classroom and click on the Tramex Certification. Let’s goo!!!
0 likes • 23d
@Keith Langskov nice bro! Good luck, reach out with any questions.
1-10 of 47
Jason Ramsay
4
79points to level up
@jason-ramsay-8638
As a licensed tile and flooring contractor, certified flooring inspector, and concrete moisture testing technician, I provide a wealth of expertise.

Active 4d ago
Joined Jan 6, 2026
Irvine, Ca
Powered by