Damaged Precast Element Collapses During Installation
During the installation of large precast façade elements inside a warehouse, a 360° Rotation telehandler was being used as lifting equipment together with a spreader beam and lifting accessories.
The precast element was lifted into its installation position and initially appeared controllable. However, the element had already suffered damage which affected its structural integrity.
During the final positioning and installation stage, once the element was placed and the load condition changed, part of the precast unit became unstable, broke away and collapsed to the ground.
A slinger was positioned immediately beside the element at the time.
As the section started to fail, the slinger recognised the movement and managed to move away quickly. Part of the heavy precast element then crashed onto the floor beside him.
He was extremely lucky.
Had he reacted only seconds later, he could have been crushed or fatally injured by the collapsing precast section.
The photographs taken afterwards show the extent of the failure, with large sections of the precast element broken and lying on the floor.
What Went Wrong
Damaged precast element allowed to proceed through the lifting operation.
Structural integrity of the element was not adequately confirmed before installation.
Damage became critical when the element reached its final position.
Part of the load suddenly became unstable.
Slinger was positioned inside the potential collapse/fall zone.
Personnel relied on the load remaining structurally intact.
The danger did not disappear simply because the load had reached its landing position.
Key Lessons Learned
Inspect the load – not only the lifting accessories.
A certified spreader beam, chains and lifting machine cannot make a damaged precast element safe.
Precast units can contain cracks, damaged edges, compromised lifting points or structural defects that may become critical when the load orientation or support conditions change.
The final installation stage can be one of the most dangerous parts of the lift.
A load may appear stable while suspended but behave differently as its weight transfers onto the structure.
Personnel must also consider the potential collapse zone, not simply the area directly underneath a suspended load.
The slinger survived because he managed to move quickly.
Running away should never be the control measure.
Safety Recommendations
Inspect every precast element before lifting.
Quarantine damaged units until assessed by a competent person.
Confirm lifting points and installation requirements against the manufacturer’s or designer’s information.
Do not assume superficial damage is cosmetic.
Establish a collapse/fall exclusion zone during installation.
Keep slingers and installers away from the potential failure path wherever practicable.
Use taglines or other suitable remote-control methods where appropriate.
Carry out a controlled trial lift and monitor the element throughout the operation.
The Lift Supervisor should stop the operation immediately if cracking, movement, deformation or unexpected behaviour is observed.
Where structural integrity is uncertain, obtain confirmation from the precast manufacturer/designer or competent engineer before continuing.
Incident Source
UK precast installation.
A 360° roto telehandler and spreader beam were being used to install a precast façade element inside a warehouse.
During final positioning, the damaged element lost stability and part of the structure broke away and fell to the ground.
A slinger positioned beside the element escaped the collapse zone immediately before impact.
No injury occurred, but the incident had clear fatal potential.
Regulatory Mapping
● LOLER Reg. 8 – The lifting operation must be properly planned, appropriately supervised and carried out safely.
● LOLER Reg. 4 – Lifting equipment and accessories must provide adequate strength and stability for the lifting operation.
● PUWER Reg. 4 – Work equipment must be suitable for the intended operation and working conditions.
● PUWER Reg. 11 – Measures must be taken to prevent people being exposed to dangerous moving equipment and associated hazards.
● BS 7121-1 – Loads, lifting points, lifting accessories, personnel positioning and the lifting method must be properly considered during planning and execution.
● CDM 2015 – Construction activities must be planned, managed and coordinated so they can be undertaken safely.
Key Point
The lifting gear can be perfect and the lift can still fail if the load itself isn’t sound.
Inspect the crane.
Inspect the accessories.
But don’t forget to inspect the load.
And never stand somewhere where your only escape plan is being quicker than a falling precast panel.
Wolf Lifting Dynamics | www.wolflifting.uk | Case Study 126
3
0 comments